Preventive Maintenance
Injector Screen and Injector
Inspect and clean brine tank and screen lter on end of brine
pickup tube once a year or when sediment appears in the
bottom of the brine tank.
Clean injector screen and injector once a year:
1. Unplug the wall-mount transformer.
2. Shut off water supply or put bypass valve(s) into bypass
position.
3. Relieve system pressure by opening valve No. 7 (at
rear) with a screwdriver (Figure 8).
4. Using a screwdriver, remove injector screen and injector
cap (Figure 9).
5. Clean screen using a ne brush. Flush until clean.
6. Using a needle-nose pliers, pull injector straight out.
7. Flush water into the injector screen recess of the valve
body to ush debris out through the injector recess.
8. Clean and ush the injector.
9. Lubricate the O-rings on the injector, injector cap and
injector screen with silicone lubricant only!
10. Reinstall the injector, injector cap and injector screen.
IMPORTANT: Do not overtighten the plastic cap. Seat the cap
lightly into position. Overtightening may cause breakage of the
plastic cap that may not be immediately evident.
11. Plug the wall-mount transformer into outlet; reset clock if
necessary.
12. Slowly open water supply valve or return bypass valve(s) to
the “service” position.
Water Meter Maintenance
The metering device used with the 960 demand controls may
require simple maintenance. In rare instances, the turbine wheel
of the water meter can collect small particles of oxidized iron,
eventually preventing the wheel from turning.
1. Shut off the water supply or put the bypass valve(s) into
the bypass position.
2. Relieve pressure by opening the Backwash Drain Valve
(the seventh back from the control) with a screwdriver
(Figure 8).
3. Loosen and remove the pipe/tube adapters or 1265
bypass from the inlet and outlet of the valve body.
4. Using a needle-nose pliers, remove the turbine from
the outlet housing. Grasp one of the four vanes of the
outer gland and pull straight out to remove turbine
assembly from the outlet of the valve (Figure 9).
5. Carefully remove the turbine wheel from the housing.
Use a toothbrush to lightly scrub the iron off the
magnet. Iron buildup on the surfaces can be removed
by soaking the wheel in a mild sodium hydrosulte
(such as RoVer*) solution for a few minutes. Flush
thoroughly with water.
6. Carefully reinstall the turbine wheel into the turbine
cage housing. Make sure that the shaft of the wheel
seats into the bearing of the cage. Reassemble the
turbine cage and check that the wheel rotates freely.
7. Reinstall the turbine cage into the outlet of the valve.
8. Reinstall the pipe/tube adapters or 1265 bypass to the
inlet and outlet of the valve.
9. Turn on the water supply or put the bypass valve(s) into
the service position and purge the air out of the system.
To check for proper meter operation, open a
downstream faucet and observe the water ow
indication, blinking colon, on the control display.