960 Avantapure Control
Figure 6
Programming
This section covers all aspects of programming the control.
The control is shipped from the factory with default values for
Hardness and Capacity. These default values will result in a
system capacity of
100 gallons (1 cubic meter). While the control will operate
with these values, they should be changed to meet the actual
operating conditions.
Note that some parameters have a single unit of measure option
such as the Rinse Time which is only entered in minutes. Other
parameters have dual units such as Salt Amount which can be
entered in pounds or kilograms. To select which units are active,
look for a comment in the NOTES column of Table 1 and Table
2. It will reference another parameter that selects which units are
active. For example, Parameter P12 (Table 3) selects U.S. units if
it is set to “0” and metric if it is set to “1.
Level I Parameters (Table 1)
Level I Parameters are identied as those that have an LED
indicator on the front panel. The green indicator illuminates
next to the name of the active control setting. The end user has
access to all of these parameters. In general, pressing the down
arrow (i) button displays the Level I Parameters in the following
order:
Time of Day
Time of Regeneration
Hardness
Salt Amount
Capacity
If you continue to press the down arrow (i) button, the
parameters start over with Time of Day. Pressing the up arrow (h)
button displays the parameters in reverse order. Refer to Table
1 for a description of these parameters and the available ranges
for each parameter.
SET
h
i

changing, press the left arrow (f) button. When you reach the
far left digit, pressing the left arrow (f) button will return you
to the far right digit.
Note: If you press and hold either the up arrow (h) button
or the down arrow (i) button for more than one second, the
ashing number will increment or decrement at the rate of 10
counts per second.
When the number is correct, press the left arrow (f) button.
The rst number stops ashing and the next number starts
ashing. You can only change the ashing number. Continue
changing numbers until you reach the desired setting. Press
the SET button. The numbers stop ashing and the control
accepts the new setting. After approximately 30 seconds,
the control starts alternating the display between Time of
Day and Capacity.
Note: If a beep sounds, the new setting is not accepted
because it was outside the allowable range. The old value
will be displayed.
Time of Day
Press the SET button. The display will show the Time of
Day with the minutes digit blinking. If you want to change
this number, press the up arrow (h) button to increase the
number or the down arrow (i) button to decrease the number.
To skip the number without changing, press the left arrow (f)
button. The rst number stops ashing and the next number
starts ashing. You can only change the ashing number.
When you have reached the far left digit, pressing the left
arrow (f) button returns you to the far right digit. Continue
changing numbers until you reach the desired setting. Press
the SET button to enter the value.
Time of Regeneration
The next value displayed is the Time of Regeneration. It
has a default value of 2:00 a.m. If this is not acceptable,
press the SET button and change the number. Press the SET
button to enter the value. If 2:00 a.m. is acceptable,
press the down arrow (i) button.
Hardness
Hardness is the next value displayed. This value is
the water hardness expressed in grains per gallon
(milligrams per liter). The default value is
10 grains/gallon (100 mg/L). If this is not acceptable,
press the SET button and enter a new value. Any value
between 3 and 250 grains per gallon (30 and
2500 milligrams per liter) is allowed. Press the SET
button to enter the new value.
Salt Amount
Salt Amount is the next value displayed. The default value
for Salt Amount is 6 pounds (2.7 kilograms) of salt; refer to
Table 2 for suggested salt settings.
Note: 